ER01 - Failed to read thermocouple

A few easy steps to check the thermocouple status and resolve the error message of the Filament Maker TWO.

Each heater attached to the barrel of the Filament Maker TWO has a dedicated thermocouple; it measures the temperatures to ensure the machine responds correctly. When the thermocouple cannot be read by the software, the system cannot guarantee the safety.

Step 1: Check the thermocouple connection

The thermocouple is connected to the heater electronics at the top of the mainboard near the barrel.

ISO_7010_W012 Turn OFF the Filament Maker TWO and remove the power plug. The heater electronics carry 110v/230v mains voltage and may cause serious health and safety risks. 
  1. Remove the hopper and hopper ring from the top plate, by turning it anti-clockwise.
  2. Remove the top plate of the Filament Maker TWO, by unscrewing the top screws. This can be done with the Allen key supplied in the maintenance kit.
  3. Find the thermocouple indicated by the machine when the error occurred.
    1. Is the thermocouple seated correctly in the heater?
    2. Is there any visual damage to the thermocouple?
    3. Is the connector properly seated in the mainboard electronics?
  4. Reconnect or reseat the thermocouple if applicable.

Step 2: Replace the thermocouple

If the thermocouple is seated correctly but still not functioning, it might malfunction internally. In this case, the thermocouple has to be replaced. Please contact us to assist with the issue.

Contact support

Please contact us by filling in a form, so we can arrange spare parts and repairs to your machine.