Filament Maker X10 – Replacing the Nozzle Cover
The nozzle cover provides insulation around the nozzle and should be replaced if it shows signs of heat damage or excessive wear.
⚠️ Important: Before starting, make sure the Filament Maker X10 is OFF and the extrusion area is completely cool.
Tools Required
- 2.5 mm (7/64") Allen key ×1
Step 1 – Confirm the Machine Is Cool
Ensure the X10 is OFF and the extrusion area is cool.
Verify the temperature through the machine's temperature settings.
Step 2 – Open the Door
Open the extrusion area door.
Step 3 – Remove the Front Panel
Remove all 4 screws securing the front panel.
Step 4 – Remove the Nozzle Plate
Slide the nozzle plate out.
The existing nozzle cover may fall off or remain seated on the nozzle.
Step 5 – Inspect the Nozzle Cover
Check the condition of the nozzle cover.
Replace it if it is worn or damaged.
Step 6 – Install the New Nozzle Cover
Press the new nozzle cover against the underside of the nozzle.
Make sure the markings on the nozzle cover are facing up.
Step 7 – Reinstall the Nozzle Plate
Slide the nozzle plate back into position.
Check that:
- The nozzle is correctly aligned.
- The nozzle cover is correctly positioned.
- The nozzle plate is correctly aligned.
- The nozzle output is not obstructed.
Step 8 – Reinstall the Front Panel
Secure the front panel using all 4 screws.
Next Step
After completing component maintenance, verify the Filament Sensor according to the recommended maintenance interval:
Filament Maker X10 – Filament Sensor Calibration
Flow
Inspecting and Replacing the Nozzle
→ Replacing the Nozzle Cover
→ Filament Sensor Calibration