The nozzle cover provides insulation around the nozzle and should be replaced if it shows signs of heat damage or excessive wear.

 

⚠️ Important: Before starting, make sure the Filament Maker X10 is OFF and the extrusion area is completely cool.

Tools Required

  • 2.5 mm (7/64") Allen key ×1
Replacement Procedure

Step 1 – Confirm the Machine Is Cool

Ensure the X10 is OFF and the extrusion area is cool.

Verify the temperature through the machine's temperature settings.

Step 2 – Open the Door

Open the extrusion area door.

Step 3 – Remove the Front Panel

Remove all 4 screws securing the front panel.

Step 4 – Remove the Nozzle Plate

Slide the nozzle plate out.

The existing nozzle cover may fall off or remain seated on the nozzle.

Step 5 – Inspect the Nozzle Cover

Check the condition of the nozzle cover.

Replace it if it is worn or damaged.

Step 6 – Install the New Nozzle Cover

Press the new nozzle cover against the underside of the nozzle.

Make sure the markings on the nozzle cover are facing up.

Step 7 – Reinstall the Nozzle Plate

Slide the nozzle plate back into position.

Check that:

  • The nozzle is correctly aligned.
  • The nozzle cover is correctly positioned.
  • The nozzle plate is correctly aligned.
  • The nozzle output is not obstructed.

Step 8 – Reinstall the Front Panel

Secure the front panel using all 4 screws.

Next Step

After completing component maintenance, verify the Filament Sensor according to the recommended maintenance interval:

Filament Maker X10 – Filament Sensor Calibration

Flow

Inspecting and Replacing the Nozzle
→ Replacing the Nozzle Cover