Firmware release notes for the Filament Maker TWO
A historical overview of official released updates added to the Filament Maker TWO firmware.
The release notes below summarize the details of every release for the Filament Maker TWO so far. Please see our dedicated article how to update the Firmware on the Filament Maker TWO.
Firmware interface overview
With each firmware update, the user interface or settings might change or move around. Learn how to use the touchscreen interface of the Filament Maker TWO.
Firmware version 0.4.1 - August 2026
This update improves torque monitoring and extrusion performance for the Filament Maker TWO.
Firmware v0.4.1 improves torque readings for both older machines with the old motor and current machines with the new motor.
For machines with the new motor, this update also resolves an issue that could cause false "Screw load too high" notifications.
The machine automatically detects which motor is installed, so no manual configuration is required.
Torque Monitoring Improvements
Torque monitoring has been improved to provide more accurate readings during extrusion.
The machine interface now displays:
- Current screw torque.
- Minimum torque.
- Maximum torque.
This makes it easier to monitor extrusion performance and identify potential material feeding issues or conditions that could cause the screw to stall.
Extrusion Improvements
Several improvements have been made to extrusion performance:
- Improved torque accuracy for both old and new motors.
- Fixed false "Screw load too high" notifications that could occur with the new motor.
- Increased the maximum selectable screw speed from 20 RPM to 30 RPM.
- Removed previous restrictions on motor strength at higher screw speeds.
Heater Improvements
Heater control has been improved for more stable and efficient heating.
This update also adds support for an additional thermocouple, including an error notification if the thermocouple cannot be read correctly.
Improved Machine Data
Additional information is now recorded for machine monitoring and troubleshooting, including:
- Minimum and maximum torque.
- Minimum and maximum motor load.
- Heatsink temperature.
Purge Preset Improvements
The default settings for the Low, Medium, High, and Super High Temp purge presets have been updated to provide improved starting settings.
Previous Firmware Updates
This release builds on several major updates introduced in earlier versions of the Filament Maker TWO firmware.
Firmware version 0.4.0 (July 2026)
Introduced support for the new locking winder hardware, automatic spool alignment correction, new purge presets, spool fullness monitoring, improved spooling and extrusion performance, expanded machine data logging, physical keyboard support through the web interface, and several system stability improvements.
Firmware version 0.3.0 (October 2025)
Introduced a major redesign of the extrusion workflow with improved process control, automatic screw start, enhanced filament sensor accuracy, independent heater control, expanded calibration tools, Safe Mode protection, and significant user interface and reliability improvements.
Firmware version 0.2.3 (August 2025)
Focused on system stability and recovery, including improved protection against failed firmware updates, improved error handling, network configuration fixes, quieter motor operation, and improved IR camera notifications.
Firmware version 0.2.2 (June 2025)
Added compatibility for the latest electronics boards while maintaining functionality with previous hardware revisions.
Firmware version 0.2.1 (June 2025)
Introduced configurable filament and spool presets, heater master ON/OFF control, improved interface labels, and automatic restoration of the last-used machine settings after restart.
Firmware version 0.1.29 (March 2025)
Added a redesigned touchscreen interface, filament roundness and infrared temperature monitoring, customizable spool presets, simplified fan controls, user-initiated firmware updates, and numerous performance and security improvements.
Firmware version 0.1.14 (December 2024)
Initial stable firmware release for the Filament Maker TWO.